Reverse osmosis purified water system










Technical parameter(Reverse osmosis host machine)
Mode number
water-produ-cing volume
(m3/h)
working pressure
(Mpa)
Desalin-ization
rate of system
(%)
Recovery rate of system
(%)
Power of high pressure pump
(kw)
Model number of memb-rane element pipe connector reference external dimensions
L* W * H(mm)

Inlet
(DN)

Outlet
(DN)
SJY-CS-02
0.2 0.95-1.75 97-99 7-17 1.5 4040 20 20 760*500*1350
SJY-CS-05 0.5 0.95-1.75 97-99 15-29 1.5 4040 20 20 955*460*1450
SJY-CS-1 1 0.95-1.75 97-99 40-50 1.5 4040 20 20 1300*600*1400
SJY-CS-2 2 0.95-1.75 97-99 50-60 3 4040 25 25 1300*800*1600
SJY-CS-5 5 0.95-1.75 97-99 50-55 5.5 4040 40 32 2400*800*1800
SJY-CS-10 10 0.95-1.75 97-99 50-60 11 8040 65 50 2800*1500*1380
SJY-CS-15 15 0.95-1.75 97-99 70-75 15 8040 80 65 3800*1500*1700
SJY-CS-20 20-25 0.95-1.75 97-99 70-75 22 8040 80 65 4800*1500*1700
SJY-CS-30 30-35 0.95-1.75 97-99 75-80 30 8040 100 80 6800*1500*1850
SJY-CS-40 40-45 0.95-1.75 97-99 75-85 37 8040 100 80 5800*1800*1900
SJY-CS-50 50-55 0.95-1.75 97-99 75-85 45 8040 125 100 6800*1800*1900
SJY-CS-60 60-65 0.95-1.75 97-99 75-85 45 8040 125 100 6800*1800*1900

Notes:
 1、Detailed analysis report on water quality should be provided by user in order that we
       can make rational deployment of reverse osmosis system, pre-treatment system and        post-treatment system according to the actual water quality and the application of        product  water before the order of goods.
 2、The above parameters are applicable to such water source as brackish water with salt        content being less than 1000mg/L.
 3、The achievable recovery rate of system is related to the concentration of indissolvable        salt and concentration polarization in water supply;
 4、The actual working pressure, water-producing volume, desalinization rate of system are        related to TDS, PH and temperature of raw water;
 5、The field installation dimensions of equipment should be based on the size of system;        space for loading and uploading membrane elements should be reserved; generally        pressure shell is a sub-system with less than 4 cores, space being more than 2m        should be made for both sides of reverse osmosis main machine; space being more        than 3m should be made for system with more than 4 cores.

   With respect of reverse osmosis membrane element for severe pollutions resulting from various kinds of reasons, we provide user with specialized cleaning service with off-line highly intensive cleaning to restore the performance of elements to the maximum extent so as to help user save energy and obtain good yield.



   
 